Oracle Database / Operations & Incident Response
ORA-08004: investigate an exhausted sequence boundary
A sequence can reach its configured maximum or minimum. Inspect its direction, bounds and cycle setting before planning a change.
Environment and inputs: Oracle Database 19c baseline · SQL*Plus-compatible SQL unless RMAN, DGMGRL, ADRCI or a host shell is specified. Check release, patch level, edition and container first.
Start with this diagnostic
Run each example in the tool named in the guide: SQL, RMAN, DGMGRL or the host command shell. Replace example names with approved values. To query DBA and V$ views, use authorized catalog access in the correct database container. Do not add broad permissions just to run an example.
SELECT sequence_owner, sequence_name, min_value, max_value, increment_by, cycle_flag, last_number FROM all_sequences WHERE sequence_owner = 'APP_OWNER' AND sequence_name = 'ORDER_SEQ';
What the results mean
The metadata describes allocation limits. Cached LAST_NUMBER needs care and is not a precise committed-row high-water mark.
Fix the cause and check again
Check the target column capacity and business uniqueness rules, then plan a supported sequence-bound adjustment or identifier redesign.
Before you make a change
Do not enable CYCLE or reset values if old identifiers can collide with existing records.