PLC
A move can be healthy at steady speed but fail during acceleration because of trajectory demand, load, drive limits or mechanics.
Drives, Motion & Axis Diagnostics1 min read
Read article : Investigate motion faults that occur only during acceleration
PLC
A brake command, drive status and actual mechanical release can differ. Gravity and stored energy make informal tests inappropriate.
Drives, Motion & Axis Diagnostics1 min read
Read article : Investigate brake-related motion symptoms without assuming the PLC command proves release
PLC
A drive can enter a configured state when cyclic commands stop, independently from the PLC's own watchdog.
Drives, Motion & Axis Diagnostics1 min read
Read article : Investigate a drive's communication-loss response in the full control design
PLC
A PLC motion block can report different outcomes across a command lifecycle. Holding an input or reusing an instance can change behavior.
Drives, Motion & Axis Diagnostics1 min read
Read article : Read motion function-block status without confusing Busy, Done and Error
PLC
A motion stop function can leave the axis in a defined stopping or locked condition until its documented lifecycle completes.
Drives, Motion & Axis Diagnostics1 min read
Read article : Investigate an axis that will not accept a move after a stop command
PLC
Direction can differ because of coordinate conventions, encoder polarity, drive configuration or mechanical transmission assumptions.
Drives, Motion & Axis Diagnostics1 min read
Read article : Investigate reversed reported axis direction without trial movement
PLC
A PLC restore may reconnect to a drive whose parameter set, firmware or motor configuration differs from the validated machine.
Drives, Motion & Axis Diagnostics1 min read
Read article : Verify drive parameters separately from the PLC application backup
PLC
A trace can reveal command and feedback timing, but collection itself can add controller load and cannot replace safe commissioning.
Drives, Motion & Axis Diagnostics1 min read
Read article : Plan a bounded motion diagnostic trace with task load in mind
PLC
A loop can behave badly because its measurement, setpoint and controller range represent different engineering quantities.
Process Control & PID Troubleshooting1 min read
Read article : Confirm PID process-variable and setpoint units before tuning
PLC
Incorrect action direction is one possible cause, but a reversed actuator or measurement interpretation can produce similar behavior.
Process Control & PID Troubleshooting1 min read
Read article : Investigate a PID loop that drives away from its setpoint
PLC
A controller block may use a configured cycle interval or calculate elapsed time from calls. Incorrect timing changes effective behavior.
Process Control & PID Troubleshooting1 min read
Read article : Check PID execution timing before changing gains
PLC
An abrupt transition can occur when internal state, tracking or setpoint does not match the current manual operating point.
Process Control & PID Troubleshooting1 min read
Read article : Investigate a PID output jump during manual-to-auto transfer